MS-2083E Portable Airborne Particle Counter

MS 2083E Portable AirborneParticle Counter

Особенности и применение

Product Feature:

  • Real-time monitoring.
  • Multi-parameter measurement.
  • Data recording and storage.
  • Lightweight and easy to carry.
  • High precision and stability.
  • Multi-size particle channel selection.

Product Application:

This product has been widely used for clean room testing in electronic manufacturing enterprises; on-site testing and leak detection of filters; monitoring of biosafety, HVAC systems, computer rooms, beverage packaging environments, production environments for pharmaceuticals and medical devices, hospital clean operating rooms, automobile painting environments, as well as production and research departments in microelectronics, biochemical products, food hygiene, fine chemicals, precision machinery, and other fields. It is also applicable to HVAC and pharmaceutical enterprises and their supervisory and regulatory departments.

Технические характеристики

Light Source Laser Diode (with a lifespan of more than 30,000 hours)
Sampling Flow Rate 2.83L/min (0.1ft³) imported sampling pump.
Particle Size Channel 0.3, 0.5, 1.0, 3.0, 5.0, 10μm; six particle size channels counted simultaneously. Signal-to-Noise Ratio at 0.3μm: ≥2.5:1
Counting Efficiency 50±10%@0.3μm, 100±10%@0.5μm
Measurement Repeatability Relative Deviation ≤±10%
Sampling Time User-defined (1 minute to 99 minutes)
Sampling Delay User-defined (1 minute to 99 minutes)
Sampling Frequency 1 to 99 times or continuous
Alarm Level Class 100 to Class 300,000 (FED-STD-209E) or ISO 5 to ISO 9 (ISO 14464-1)
Testing Mode Single/Repeat/Continuous/Timed/Average
Data Memory Capacity 1,000 sets of measurement data
Error Indication Exceeds maximum count/Laser power attenuation/Flow rate deviation (>±5%)/Low battery
Communication Interface USB
Maximum Communication Rate 12MBPS
Charging Time 3 hours for quick charge, 12 hours for initial charge
Self-Cleaning Time ≤10 minutes
Maximum Concentration ±5% at 2,000,000 particles/ft³ (71,000 particles/L)
Screen Display Mode LCD touchscreen
Printing Mode External printer with Epson ribbon
Sampling Location Number 1,000 sets
Counting Mode Cumulative count/Particle size range
Power Supply Rechargeable Ni-MH battery (6V/2500mAh) or AC adapter (input 100~240V)
Battery Operating Time Continuous testing time >6 hours
Dimensions 220*40*120mm
Weight 1 kg
Environmental Conditions Operating temperature: 15~35℃ Operating humidity: 10~85% RH Storage temperature: -10~50℃ Storage humidity: 10~85% RH
Verification Standards JIS-B-9921 (1997), ASTM F649-01, ASTM F328-98 (NIST traceable), JJG 547-1988, GB/T 6167-2007, JJF 1190-2008
UCL Criterion ISO 14644 & FS 209E

Стандартная комплектация

Standard Accessories AC adapter
Battery charger
Zeroing filter
Isokinetic sampling probe
Portable protective case
Operation manual
Factory calibration report
Bluetooth printer
Data export software